LMA3729/Upward tone analog silicon microphone

Product Description

Reliability Experiment Standards


可靠性实验标准(部分)

No.

Experimental project

Number of test samples

Test conditions

Judgment criteria

1

Drop test

39pcs/3lot

Workpiece weight 150g ± 10g, height 1.5m; (6 sides+4 corners) * 4 drops

△Sens≤1dB

2

Vibration testing

39pcs/3lot

12 minutes in each of the X/Y/Z directions, with a frequency of 20-2000Hz and a peak acceleration of 20g

3

free fall test 

39pcs/3lot

Drum drop machine, drop height of 1m, frequency of 300 times

4

Structural impact

39pcs/3lot

10000g, 0.1ms pulse width, 3 times in X/Y/Z directions, recovered for 2 hours after the experiment

5

Anti blowing

39pcs/3lot

0.45MPa, 3cm away from the sound inlet, lasting for 10s, the air gun diameter needs to be greater than the product diameter

Meet specification requirements

6

ESD experiment

3pcs/3lot

HBM: 100pF, 1500ohms, ± 3kV direct contact I/O pin discharge

Meet specification requirements

7

Temperature shock (pre-treatment)

25pcs/3lot

-40 ℃/15min, 125 ℃/15min, cycle 100 times, and recover for 2 hours after the test

△Sens≤3dB

8

HAST testing (preprocessing)

30pcs/3lot

130 ℃/85% RH/96 hours, the product is at the upper limit voltage of the specifications, and it will recover for 2 hours after the test

9

High temperature storage

25pcs/3lot

105 ± 3 ℃, 1000H, recovered for 2H after test

10

Low temperature storage

25pcs/3lot

-40 ± 3 ℃, 1000H, recovered for 2H after the test

11

High temperature power on

77pcs/3lot

105 ± 3 ℃, product at the upper limit voltage of specifications, 1000H, restored to 2H after the test

12

Low temperature power on

32pcs/3lot

-40 ± 3 ℃, product at the upper limit voltage of specifications, 1000H, restored to 2H after the test 

13

High temperature and high humidity power on (pre-treatment)

25pcs/3lot

85 ± 3 ℃, 85% RH, the product is at the upper limit voltage of the specification (3.6V), 1000H, recovered for 2H after the test


典型规格频响和相位曲线

LMA2718T/上进音(图1)

1. The above frequency response curve and phase curve are typical parameter curves of LMA2718B381-A2NC noise reduction silicon microphone;


2. In addition to having high requirements for signal-to-noise ratio, the flatness of the low-frequency response (below 50Hz) and the consistency of the phase curve are crucial factors for ANC noise reduction silicon microphone. The low frequency response of the ANC noise reduction silicon microphone in Lingmai Acoustics can extend its flatness to around 20Hz, providing effective protection for the pickup process of the low frequency noise reduction function;